Trace width and temperature rise: IPC-2221 or IPC-2152?

5 min read

How to size a trace for the current it carries, what the two standards say, and why the newer one often changes the answer.

A trace that is too narrow for its current heats up through Joule losses. At best, the voltage drop upsets a component's supply; at worst, the heat ages the laminate, lifts the copper or opens the trace. Sizing therefore starts from three inputs: the continuous current, the copper thickness and the acceptable temperature rise above ambient.

The historical rule: IPC-2221

IPC-2221 gives an empirical relationship between current, cross-section and temperature rise:

I = k · ΔT0.44 · A0.725

with I in amps, ΔT the temperature rise in °C, A the trace cross-section in mil² and k = 0.048 for an external layer, 0.024 for an internal layer.

Example: 2 A, 10 °C rise, 35 µm (1 oz) copper. The required cross-section is about 42 mil² on an external layer, i.e. a trace of about 0.78 mm. On an internal layer, the formula asks for about 110 mil², i.e. more than 2 mm.

What IPC-2152 changes

Those curves come from old measurements made in conditions that no longer match today's boards. IPC-2152 is based on new measurements and accounts for parameters that really matter: board thickness, nearby copper planes and board material.

In practice, the IPC-2221 rule is often very conservative, especially for internal traces, which shed heat well through the dielectric and neighbouring planes. Following IPC-2152 saves board space without adding risk, and also reveals cases where a "compliant" trace still runs hot because it is thermally isolated.

Commonly overlooked points

Check on the prototype

Calculation gives a starting point; measurement confirms it. On the first boards, a thermal camera or a thermocouple at rated current validates the real temperature rise before the layout is frozen.